• TP7M High Accuracy Touch Probe

    $5,295.00

    The TP7M uses strain gauge technology which provides higher accuracy than standard touch trigger probes, The TP7M is a multi-wired probe and must be used with the PH10M motorised probe head or the PH6M fixed probe head. It is autojointed, which provides the autochange function required on many DCC CMMs.

    Principal Application: FMS and automated systems
    Mounting: Multiwired autojoint
    Suitable interface: PI 7-2
    Sense directions: 6 axis ±X, ±Y, ±Z

    2sigma at stylus tip
    Trigger 1 0.25µm 0.00001in
    Low force 0.25µm 0.00001in

    Pre-travel variation (XY Plane)
    Trigger 1 ±0.25µm ±0.00001in
    Low force ±0.50µm ±0.00002in

    Extended force
    Trigger Force XY Plane 0.02N 0.07oz
    Low force

    Trigger Force Z Axis 0.15N 0.53oz
    Low force

    Overtravel Force XY Plane 0.78N 2.75oz
    Low force

    Overtravel Force Z Axis 11.75N 41.44oz

    Test conditions:
    Stylus length 50mm 1.97in
    Stylus velocity 480mm/min 18.90in/min
    Stylus force
    Max extension on 200mm 7.87in

    Weight (g) 85
    Height (mm) 52

  • TP2-5W Touch Probe

    $3,595.00

    TP2 5-Way is the industry standard probe for most CMM applications. It’s compact dimensions  are ideal for probing into restricted component features.

    • Sense Directions: 5-Way: +/- X,Y,+Z
    • 2(sigma) Uni-Directional Repeatability: 0.35 microns
    • Pre-Travel Variations: +/- 0.80 microns
    • Stylus Force Range: 7-15g
    • Stylus Overtravel: XY Plane +/- 14 degrees
    • + Z Axis 4.5 mm @7g
    • 3.0 mm @ 15g
    • Max. Extension on: PH9 200mm
    • PH10M 300mm
    • Suitable Interfaces: PI4, PI7, PI9
    • Stylus Thread Size: M2
    • Mounting Options: M8 thread
    • Test Conditions: 10mm stylus @ 8mm/s with trigger force of 7-8 g
  • TP6A Autojoint Touch Probe

    $3,595.00

    TP6 combines the robust characteristics of the TP1 (S) with the flexibility of the TP2. It can be used on manual or DCC CMM’s along with Renishaw’s vast range of heads and extensions.

    TP6A incorporates an autojoint for use with the Renishaw Autochange System, or for manual probe change. The TP6A allows for fast probe exchange without redatuming.

    • Sense Directions: +/- X,Y,+Z
    • 2(sigma) Uni-Directional Repeatability: 0.35 microns
    • Pre_Travel Variations: +/- .60 microns
    • Stylus Force Range: 10-30g
    • Stylus Overtravel: XY Plane +/- 22 degrees
    • + Z Axis 6.5 mm @12g
    • 3.0 mm @ 30g
    • Max.Extensions on: PH9 with TP6 100mm
    • PH9A with TP6A 50mm
    • PH10M with TP6 200mm
    • PH10M with TP6A 200mm
    • Suitable Interfaces: PI4, PI7, PI9
    • Stylus Thread Size: M3
    • Test Stylus Thread Size: 21mm
    • Mounting Options: (TP6) M8 thread
    • (TP6A) Autojoint
    • Test Conditions: 21mm stylus @ 8mm/s with trigger force of 11-13g

     

     

  • TP6 Heavy Duty Touch Probe

    $3,485.00

    TP6 combines the robust characteristics of the TP1 (S) with the flexibility of the TP2. It can be used on manual or DCC CMM’s along with Renishaw’s vast range of heads and extensions.

    TP6A incorporates an autojoint for use with the Renishaw Autochange System, or for manual probe change. The TP6A allows for fast probe exchange without redatuming.

    • Sense Directions: +/- X,Y,+Z
    • 2(sigma) Uni-Directional Repeatability: 0.35 microns
    • Pre_Travel Variations: +/- .60 microns
    • Stylus Force Range: 10-30g
    • Stylus Overtravel: XY Plane +/- 22 degrees
    • + Z Axis 6.5 mm @12g
    • 3.0 mm @ 30g
    • Max.Extensions on: PH9 with TP6 100mm
    • PH9A with TP6A 50mm
    • PH10M with TP6 200mm
    • PH10M with TP6A 200mm
    • Suitable Interfaces: PI4, PI7, PI9
    • Stylus Thread Size: M3
    • Test Stylus Thread Size: 21mm
    • Mounting Options: (TP6) M8 thread
    • (TP6A) Autojoint
    • Test Conditions: 21mm stylus @ 8mm/s with trigger force of 11-13g
  • TP1S Touch Probe

    $3,285.00

    TP1S/TP1SM

    A robust and reliable probe which is especially suited for manual CMMs. Two versions
    differing in plug socket orientations are available: TP1S-cable connects vertically TP1SM-cable connects horizontally.

    • Sense Directions: +/- X,Y,+Z
    • 2(sigma) Uni-Directional Repeatability: 0.5 microns
    • Pre-Travel Variations: +/- 2.0 microns
    • Stylus Force Range: 10-50g
    • Stylus Overtravel: XY Plane +/- 19.5 degrees
    • + Z Axis 8.5 mm @15g
    • 5.0 mm @ 50g
    • Suitable Interfaces: PI4, PI7, PI9, PI12
    • Stylus Thread Size: M3
    • Mounting Options: Shank to suit your CMM
    • Test Conditions: 31mm stylus @ 8mm/s with trigger force of 15g

     

  • TP20 Probe with Quickchange Modules

    TP20 – THE NEW MODULE CHANGING TOUCH TRIGGER PROBE

    One of the most common sources of error on standard design touch probes is when using long styli. That requires a manual adjustment of the probe’s triggering force to compensate for the leverage of the stylus. Often the trigger force is not adjusted at all, or is not reduced when a shorter stylus is remounted. The TP20 provides three quick-change stylus modules, preset with trigger forces required for 10mm, 25mm and 50mm long styli.

    TP20 is a new kinematic touch trigger probe that gives its users the ability to change stylus configurations, either manually or automatically without requalifying. A direct replacement for the industry standard TP2, the TP20 system is easily retrofitted to both manual and DCC co-ordinate measuring machines (CMMs) with existing TP2 or TP6 installations.

    The TP20 probe consists of two parts – a probe body and a detachable probe module that contains the kinematic touch sensor and carries the stylus assembly. The module is connected to the probe body by a highly repeatable magnetic coupling, which allows the exchange of modules without the need to requalify. The probe body has a standard M8 screw connector, which enables simple fitment to all CMMs with a Renishaw M8 probe head, including PH6, MH8 and PH9. Fitment to ‘autojoint’ probe heads is also possible with a suitable Renishaw ‘PAA’ adaptor.

    The new optional MCR20 Module Change Rack, stores up to 6 probe modules, enabling automatic changing of different stylus configurations under measurement program control. Probe triggers are inhibited during module changing by a proximity switch system, which eliminates the need for an electrical connection to the MCR20.

    The TP20 system extends the availability of fast stylus changing to users of manual CMMs and, with software available from suppliers of CMMs, facilitates automatic changing in most current TP2 or TP6 applications on automated machines.

    Sense Directions: 5 Way +/-X, +/-Y, +Z
    Mounting Options: M8 Thread
    Stylus Thread Size: M2
    Suitable Interfaces: PI4, PI4-2, PI6, PI7, PI200

    Standard Medium Extended
    ———————————————————————————————————

    • Unidirectional Repeatability 2(sigma): 0.35 0.50 0.65
    • 2D Form Measurement Deviation: +/-0.8 +/-1.0 +/-2.0
    • Test Conditions: Steel 10mm long, 4mm ball stylus. Trigger speed 8mm/s
    • Trigger Force (XY): 8g 10g 10g
    • Nominal at Stylus Tip (Z): 75g 190g 320g
    • Overtravel Force (XY): 20-30g 20-40g 20-50g
    • Maximum at Stylus Tip (Z): 350g 700g 1000g
    • Overtravel (XY): +/-14 degrees +/-14 degrees +/-14 degrees
    • Displacement (Z): 4.0mm 3.7mm 2.4mm